With NVIDIA GB200/AMD MI350 chips exceeding 1200W, cable channel temperatures in data centers reach 110℃+. 2025 NFPA 262 updates mandate:
OFNP-rated cable Dsmax ≤50 (vs. ≤75 legacy)
Flame spread ≤1.5m (UL 1685 Cat.5)
Per BCC Research, global flame-retardant PVC cable market for AI data centers will hit $4.2B in 2025, OFNP-grade demand growing at 35% CAGR.
EP-Y011 Innovations (Patent CN202410356789.2)
Molybdate-Mg(OH)₂ Core-Shell Structure
40% molybdate (smoke suppression) + 60% Mg(OH)₂ (flame retardancy)
Forms ceramic char layer at 250°C, OI=46% (ASTM D2863)
Record-Low Smoke Density
Test Condition | Traditional Sb₂O₃ | EP-Y011 |
---|---|---|
Flaming Dsmax (GB/T 8323) | 320 | 176 |
Non-flaming Dsmax (GB/T 8323) | 480 | 222 |
UL 1685 Flame Spread | 2.8m | 0.9m |
Source: Konnod Lab (2025Q3) |
Electrical Performance Assurance
Volume resistivity >1×10¹⁵ Ω·cm (IEC 60093)
Dk=3.2 at 1MHz, compatible with 400G optical modules
Customer | Application | Results |
---|---|---|
Huawei Cloud | Liquid-cooled server cables | NFPA 262 Dsmax=42 (limit 50) |
Equinix | North America AI hub | UL 1685 Cat.5 certified (0.7m spread) |
GDS Holdings | HVDC power systems | <5% smoke density shift after 1000h damp heat |
Zero Hazardous Substances: Passed RoHS/REACH SVHC 239 tests (SGS-REA25-0886)
Non-Migrating: Water solubility <5g/L (25°C), no long-term performance loss
Cost Efficiency: 5phr loading (vs. 8-10phr traditional), 18% cable cost reduction
10,000-ton Zhuhai plant (Q4 2025) features:
▶ Supercritical CO₂ drying: D50=1-4μm
▶ Moisture content ≤0.3% (industry avg. 1.2%)
▶ AI vision QC system (99.98% defect detection)
With NVIDIA GB200/AMD MI350 chips exceeding 1200W, cable channel temperatures in data centers reach 110℃+. 2025 NFPA 262 updates mandate:
OFNP-rated cable Dsmax ≤50 (vs. ≤75 legacy)
Flame spread ≤1.5m (UL 1685 Cat.5)
Per BCC Research, global flame-retardant PVC cable market for AI data centers will hit $4.2B in 2025, OFNP-grade demand growing at 35% CAGR.
EP-Y011 Innovations (Patent CN202410356789.2)
Molybdate-Mg(OH)₂ Core-Shell Structure
40% molybdate (smoke suppression) + 60% Mg(OH)₂ (flame retardancy)
Forms ceramic char layer at 250°C, OI=46% (ASTM D2863)
Record-Low Smoke Density
Test Condition | Traditional Sb₂O₃ | EP-Y011 |
---|---|---|
Flaming Dsmax (GB/T 8323) | 320 | 176 |
Non-flaming Dsmax (GB/T 8323) | 480 | 222 |
UL 1685 Flame Spread | 2.8m | 0.9m |
Source: Konnod Lab (2025Q3) |
Electrical Performance Assurance
Volume resistivity >1×10¹⁵ Ω·cm (IEC 60093)
Dk=3.2 at 1MHz, compatible with 400G optical modules
Customer | Application | Results |
---|---|---|
Huawei Cloud | Liquid-cooled server cables | NFPA 262 Dsmax=42 (limit 50) |
Equinix | North America AI hub | UL 1685 Cat.5 certified (0.7m spread) |
GDS Holdings | HVDC power systems | <5% smoke density shift after 1000h damp heat |
Zero Hazardous Substances: Passed RoHS/REACH SVHC 239 tests (SGS-REA25-0886)
Non-Migrating: Water solubility <5g/L (25°C), no long-term performance loss
Cost Efficiency: 5phr loading (vs. 8-10phr traditional), 18% cable cost reduction
10,000-ton Zhuhai plant (Q4 2025) features:
▶ Supercritical CO₂ drying: D50=1-4μm
▶ Moisture content ≤0.3% (industry avg. 1.2%)
▶ AI vision QC system (99.98% defect detection)